Skip to content
Intraspinal Injection Allopathic

Anespine 0.5%+8% intraspinal injection

Generic: Bupivacaine Hydrochloride + Dextrose

Company: Square Pharmaceuticals PLC. Prices are as listed on BestinMeds; your pharmacy price may differ.

Strength0.5%+8%
PackNot listed yet

Reviewed by: not listed yet. Source: not listed yet.

Last updated September 7, 2024.

Compare

Same generic, same strength

Sorted by price per intraspinal injection. Ask your pharmacist before you switch brands.

Bupivacaine Hydrochloride + Dextrose 0.5%+8% intraspinal injections

Prices as listed on BestinMeds.

2 brands listed
Bupicain Heavy, box of 1028.00 taka per intraspinal injection
Anespine, box of 10 (this medicine)30.20 taka per intraspinal injection

Advertisement

Google Ads 970 x 250
Google Ads 300 x 250
Medicine guide

About this medicine

What this medicine is for, how to take it, and what to watch for.

Read the full Bupivacaine Hydrochloride + Dextrose guide

Indications

Subarachnoid anesthesia Bupivacaine Hydrochloride & Dextrose is indicated for- Bupivacaine is indicated for lower abdominal surgery (including Caesarean section), urological and lower limb, including hip surgery, lasting 1.5 to 3 hours. Bupivacaine are indicated for intrathecal (subarachnoid, spinal) anesthesia for surgical and obstetrical procedures. ... Read more Bupivacaine Hydrochloride & Dextrose is indicated for- Bupivacaine is indicated for lower abdominal surgery (including Caesarean section), urological and lower limb, including hip surgery, lasting 1.5 to 3 hours. Bupivacaine are indicated for intrathecal (subarachnoid, spinal) anesthesia for surgical and obstetrical procedures. Bupivacaine produces motor blockade of the abdominal muscles makes the solution suitable for performance of abdominal surgery lasting 1.5-2 hours. The duration of motor blockade does not exceed the duration of analgesia.

Dosage and administration

The doses recommended below should be regarded as a guide for use in the average adult. Spinal anaesthesia for surgery: 2-4 ml (10-20 mg Bupivacaine hydrochloride). The spread of anaesthesia obtained with Bupivacaine depends on several factors including the volume of the solutions and the position if the patients during and following the injection. When injected in the L3-L4 intervertebral space with the patient in the sitting position, 3 ml of Bupivacaine spreads to the T7- T10 spinal segments. With the patient receiving the injection in the horizontal position and then turned supine, the blockade spine spreads to T4-T7 spinal segments. It should be understood that the level of spinal anaesthetic can be unpredictable in a given patient.

Side effects

The adverse reaction profile for Bupivacaine is similar to those for other long acting local anesthetics administered intrathecally. Adverse reactions caused by the drug are difficult to distinguish from the physiological effects of the nerve block (e.g. decrease in blood pressure, bradycardia, temporary urinary retention), events caused directly (e.g. nerve trauma) or indirectly (e.g. epidural abscess) by the needle puncture or events associated to cerebrospinal leakage (eg. postdural puncture headache).

Precautions and warnings

Bupivacaine should be given cautiously to the elderly, the debilitated patients and to children, to patients with epilepsy, respiratory impairment, impaired cardiac conduction, bradycardia, severe shock; porphyria; myasthenia gravis. Myocardial depression may be more severe and more resistant to treatment.

Pregnancy and lactation

It is reasonable to assume that a large number of pregnant women and women of child-bearing age have been given Bupivacaine. No specific disturbances to the reproductive process have so far been reported, e.g. no increased incidence of malformations. It should be noted that the dose should be reduced in patients in the late stages of pregnancy With recommended doses, Bupivacaine enters breast milk in such small quantities that there is generally no risk of affecting the breast feed child. At maternal serum levels of up to 0.45 µg/ml produced by the epidural use of Bupivacaine for vaginal delivery, Bupivacaine could not be detected in breast milk during the first 24 hours after delivery (detection limit 0.02 µg/ml).

Clinical details

BestinMeds shares medicine information to help you compare. It does not replace advice from your doctor or pharmacist.

Advertisement

Google Ads 970 x 250
Google Ads 300 x 250

Advertisement

Google Ads 970 x 250
Google Ads 300 x 250